Loading...
SINAMICS V20 Inverter
28 A5E37281078-003, 05/2016
Parameter
Description
Range
Factory default
Acc.
level
1
Trip reset after power on, P1211 disabled
2
Restart after mains blackout, P1211 disabled
3
Restart after mains brownout or fault, P1211 enabled
4
Restart after mains brownout, P1211 enabled
5
Restart after mains blackout and fault, P1211 disabled
6
Restart after mains brown- /blackout or fault, P1211 enabled
7
Restart after mains brown- /blackout or fault, trip when P1211 expire
8 Restart after mains brown- /blackout with F3 and leave an interval in seconds determined by P1214,
P1211 disabled
P1215
Holding brake enable
0 - 1
0
2
0
Motor holding brake disabled
1
Motor holding brake enabled
P1216
Holding brake release delay [s]
0.0 - 20.0
1.0
2
P1217
Holding time after ramp down [s]
0.0 - 20.0
1.0
2
P1227[0...2]
Zero speed detection monitoring time [s]
0.0 - 300.0
4.0
2
P1232[0...2]
DC braking current [%]
0 - 250
100
2
P1233[0...2]
Duration of DC braking [s]
0.00 - 250.00
0.00
2
P1234[0...2]
DC braking start frequency [Hz]
0.00 - 550.00
550.00
2
P1236[0...2]
Compound braking current [%]
0 - 250
0
2
P1237
Dynamic braking
0 - 5
0
2
0
Disabled
3
20 % duty cycle
1
5 % duty cycle
4
50 % duty cycle
2
10 % duty cycle
5
100 % duty cycle
P1300[0...2]
Control mode
0 - 19
0
2
0
V/f with linear characteristic
5
V/f for textile applications
1
V/f with FCC
6
V/f with FCC for textile applications
2
V/f with quadratic characteristic
7
V/f with quadratic eco
3
V/f with programmable characteristic
19 V/f control with independent voltage set-
point
4
V/f with linear eco
P1310[0...2]
Continuous boost [%]
0.0 - 250.0
50.0
2
P1311[0...2]
Acceleration boost [%]
0.0 - 250.0
0.0
2
P1312[0...2]
Starting boost [%]
0.0 - 250.0
0.0
2
r1348
Economy mode factor [%]
-
-
2
P1800[0...2]
Pulse frequency [kHz]
2 - 16
4
2
P1820[0...2]
Reverse output phase sequence
0 - 1
0
2
0
Forward
1
Reverse the Motor
P1900
Select motor data identification
0 - 2
0
2
0
Disabled
2
Identification of all parameters in standstill
P2000[0...2]
Reference frequency [Hz]
1.00 - 550.00
50.00
2
P2010[0...1] USS / MODBUS baudrate 6 - 12 [0] 6
[1] 8
2
6
9600 bps
10
76800 bps
7
19200 bps
11
93750 bps
8
38400 bps
12
115200 bps
9
57600 bps
Index:
[0]
USS / MODBUS on RS485
[1]
USS on RS232 (reserved)
P2011[0...1]
USS address
0 - 31
0
2