Examples
4.1 Axis monitoring
Basic logic functions: Axis monitoring, protection zones (A3)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
67
N83 $AC_WORKAREA_CS_LIMIT_PLUS[2,Z] = –600
N90 $AC_WORKAREA_CS_PLUS_ENABLE[2,A] = FALSE
N92 $AC_WORKAREA_CS_MINUS_ENABLE[2,A] = FALSE
Activate working area limitation group 2
In order to activate the working area limitation group 2, following instruction must exist in the
part program:
...
N100 WALCS2 ...
...