Detailed description
2.2 Mode groups
Basic logic functions: Mode group, channel, program operation, reset response (K1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
23
2.2.2 Mode change
Introduction
A mode change is requested and activated via the mode group interface (DB11, ...). A mode
group will either be in AUTOMATIC, JOG, or MDA mode, i.e., it is not possible for several
channels of a mode group to take on different modes at the same time.
What mode transitions are possible and how these are executed can be configured in the
PLC program on a machine-specific basis.
Note
The mode is not changed internally until the signal "Channel status active" is no longer
pending. For error-free mode change however, all channels must assume a permissible
operating mode.
Possible mode changes
The following table shows possible mode changes for one channel.
Table 2-1 Mode change
AUTOMATIC JOG MDA
from AUTO MDA JOG without
handwheel
AUTO
To RESET Interrupt RESET Interrupt Interrupt RESET Interrupt active Interrupt
AUTOMATIC X X X
JOG X X X X X
MDA X X X X
Possible mode changes are shown by an "X".

Table of Contents

Other manuals for Siemens Sinumerik 840 sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840 sl and is the answer not in the manual?

Siemens Sinumerik 840 sl Specifications

General IconGeneral
BrandSiemens
ModelSinumerik 840 sl
CategoryControl Unit
LanguageEnglish

Related product manuals