Detailed description
2.12 Block descriptions
Basic logic functions: PLC basic program solution line (P3 sl)
174 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Description of formal parameters
The table below lists all formal parameters of the Diagnostics function:
Formal parameters of diagnostics function
Signal Type Type Value range Remark
Func I INT 0, 1, 2 Function
0: Deactivate
1: Signal recorder
2: Data trigger
Parameters for function 1
Signal_1 to
Signal_8
I BOOL Bit signals checked for change
NewCycle I BOOL See the "Signal recorder" description above
Var1 I BYTE Additional value
Var2 I INT Additional value
VAR I INT Additional value
BufDB I INT Ring buffer DB no.
ClearBuf I BOOL Delete ring buffer DB and reset pointer
BufAddr
BufAddr I/O INT Target area for read data
Parameters for function 2
DataAdr I POINTER Pointer to word to be tested
TestVal I WORD Comparison value
AndMask I WORD See description
TestIsTrue A BOOL Result of comparison

Table of Contents

Other manuals for Siemens Sinumerik 840 sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840 sl and is the answer not in the manual?

Siemens Sinumerik 840 sl Specifications

General IconGeneral
BrandSiemens
ModelSinumerik 840 sl
CategoryControl Unit
LanguageEnglish

Related product manuals