Detailed description
2.3 Setpoint /actual-value system
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
54 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
'5,9(B(1&B5$7,2B180(5$>Q@
'5,9(B$;B5$7,2B180(5$>Q@
'5,9(B$;B5$7,2B'(120>Q@
,17B,1&5B3(5B00
/($'6&5(:B3,7&+
'5,9(B(1&B5$7,2B'(120>Q@
,QWHUQDOLQFUHPHQWVPP
(QFRGHULQFUHPHQWVPP
(1&B5(62/>Q@LQWHUQDOPXOWLSOLFDWLRQ
⇒ MD30300 $MA_IS_ROT_AX = 0
MD31000 $MA_ENC_IS_LINEAR[0] = 0
MD31040 $MA_ENC_IS_DIRECT[0] = 0
MD31020 $MA_ENC_RESOL[0] = 2048
MD31030 $MA_LEADSCREW_PITCH = 10
MD31080 $MA_DRIVE_ENC_RATIO_NUMERA[0] = 1
MD31070 $MA_DRIVE_ENC_RATIO_DENOM[0] = 1
MD31060 $MA_DRIVE_AX_RATIO_NUMERA[0] = 5
MD31050 $MA_DRIVE_AX_RATIO_DENOM[0] = 1
MD10200 $MN_INT_INCR_PER_MM = 10000
PPLQFUPP
,QWHUQDOLQFUHPHQWVPP
(QFRGHULQFUHPHQWVPP
Result:
1 encoder increment corresponds to 0.004768 increments of the internal unit. In practice, the
available encoder resolution should not be resolved more accurately than the internal
computational resolution.