Supplementary conditions
3.2 Output behavior
Basic logic functions: Auxiliary Function Output to PLC (H2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
57
Auxiliary function: M1 (conditional stop)
Overriding the parameterized output behavior
The parameterized output behavior of the auxiliary function M1 is overridden by the output
behavior defined in the following machine data:
MD20800 $MC_SPF_END_TO_VDI, Bit 1 (subprogram end / stop to PLC)
Bit Value Meaning
0 The auxiliary function M01 (conditional stop) is always output to the PLC. A quick
acknowledgement is ineffective, because M01 is permanently assigned to the first
auxiliary function group and is therefore always output at the end of the block.
1
1 The auxiliary function M01 (conditional stop) is only output to the PLC, if the function:
"Programmed stop" is activated via the HMI user interface.
In the case of a quick acknowledgement, the M1 is output to the PLC during the motion.
While the function is not active, this does not interrupt continuous-path mode.
Part program blocks without traverse movement
In a part program block without a traverse movement, all auxiliary functions are output in a
block immediately, irrespective of their parameterized output behavior.

Table of Contents

Other manuals for Siemens Sinumerik 840 sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840 sl and is the answer not in the manual?

Siemens Sinumerik 840 sl Specifications

General IconGeneral
BrandSiemens
ModelSinumerik 840 sl
CategoryControl Unit
LanguageEnglish

Related product manuals