4.3 Installing ePS Reporting Services
eP-Satellite server
76 Operating Instructions, 06/2009
4.3 Installing ePS Reporting Services
Installing the database component
Relevant servers eP-Satellite application reporting database server
The satellite.settings file created in Section Preparing for installation (Page 32) is used for
installing ePS Reporting Services.
Unzip archive "Reporting_install _x.x.x.x.zip": The installation package must be located no
more than one level below the drive letter; otherwise, installation problems relating to the
depth of the directory will arise. It must be ensured that none of the extracted files including
subfolders has read-only access.
Example: C:\temp\server_install_x.x.x.x.
The adapted settings file must be copied to the \tools\UserSettings directory of the unzipped
installation package.
In the unzipped installation package, edit the setup_Reporting_production.bat script under
\tools\install, change parameter "production.settings" to "satellite.settings", then run the
script.
Install DatabaseServer for ePS Reporting YES
Install Web Server for ePS Reporting NO
Installing the web server component
Relevant servers eP-Satellite application reporting web server
The satellite.settings file created in Section Preparing for installation (Page 32) is used for
installing ePS Reporting Services.
Unzip archive "Reporting_install _x.x.x.x.zip": The installation package must be located no
more than one level below the drive letter; otherwise, installation problems relating to the
depth of the directory will arise. It must be ensured that none of the extracted files including
subfolders has read-only access.
Example: C:\temp\server_install_x.x.x.x.
The adapted settings file must be copied to the \tools\UserSettings directory of the unzipped
installation package.
In the unzipped installation package, edit the setup_Reporting_production.bat script under
\tools\install, change parameter "production.settings" to "satellite.settings", then run the
script.
Install DatabaseServer for ePS Reporting NO
Install Web Server for ePS Reporting YES

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based

Related product manuals