1 2 3 4 5 6 7 8 9 10 Default device name
o󹪜 on on o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 pp72x48pn6
on o󹪜 on o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 pp72x48pn5
o󹪜 o󹪜 on o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 pp72x48pn4
on on o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 pp72x48pn3
o󹪜 on o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 pp72x48pn2
on o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 pp72x48pn1
o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 o󹪜 pp72x48pn
Note
A newly set PROFINET address will only come into e󹪜ect after power OFF/ON.
12.3.4.4 X111, X222 and X333 digital inputs/outputs
Cable speci󹪝cation
Connectors: 50-pin ribbon cable connectors
50-pin insulation displacement connectors with cable grip, ribbon cables and terminal
converters
are required for connecting digital inputs and outputs.
The required connecting cables (ribbon cables) must be provided by the user
.
Max. cable length: 30 m
Pin assignment
Table 12-42 Pin assignment X111
Pin Signal name Type Pin Signal name Type
1 M GND 2 P24OUT VO
3 DI 0.0 I 4 DI 0.1 I
5 DI 0.2 I 6 DI 0.3 I
7 DI 0.4 I 8 DI 0.5 I
9 DI 0.6 I 10 DI 0.7 I
11 DI 1.0 I 12 DI 1.1 I
13 DI 1.2 I 14 DI 1.3 I
15 DI 1.4 I 16 DI 1.5 I
17 DI 1.6 I 18 DI 1.7 I
19 DI 2.0 I 20 DI 2.1 I
21 DI 2.2 I 22 DI 2.3 I
23 DI 2.4 I 24 DI 2.5 I
25 DI 2.6 I 26 DI 2.7 I
27 Not assigned - 28 Not assigned -
Connectable components
12.3 PP 72/48D PN 2/2A PN
NCU 1740
138 Equipment Manual, 10/2021, A5E51087503B AA