Application planning
5
5.1 Supplementary electrical conditions
5.1.1 Grounding concept
Components
The SINUMERIK ONE system consists of several individual components that have been designed
so that the system complies with the appropriate EMC and safety standards. The individual
system components are:
Numerical Control Unit (NCU):
Machine Control Panel MCP, Machine Push Button Panel MPP
Keyboard
Operator panels (operator panel front + TCU / SIMATIC IPC for SINUMERIK)
Distributor box and handheld unit
S7-1500 I/O devices
Grounding measures
The individual modules are attached to a metal cabinet panel. Insulating paints on the mounting
points must be removed.
It is permissible to have a cluster of operator components for ground connection / equipotential
bonding.
Example: The control panel on the swivel arm.
It is su󹪟cient in this instance to connect the ground connections of, for example, the SIMATIC
IPC for SINUMERIK, TCU and operator panel front using a cable and to route a shared grounding
conductor to the central ground connection in the control cabinet.
More information
More information about EMC installation guidelines can be found under:
Con󹪝guration Instructions, EMC installation guideline (
https://
support.industry.siemens.com/cs/document/60612658/emc-design-guidelines-
con󹪝guration-manual-01-2012?dti=0&lc=en-WW)