The cycle time of the analog value accumulation is limited by the PLC cycle.
Table 12-51 Technical speci󹪝cations in the "voltage output" operating mode
Parameter Value
Output range (rated value) - 10 V to + 10 V
Permitted overrange - 10.5 V to + 10.5 V
Resolution 16 bits (including sign)
Accuracy +/- 0,5 %
Max. load current -3 mA to +3 mA
Table 12-52 Technical speci󹪝cations in the "current output" operating mode
Parameter Value
Output range (rated value) - 20 mA to + 20 mA
Permitted overrange - 20.2 mA to + 20.2 mA
Resolution 16 bits (including sign)
Accuracy +/- 0,5 %
Load impedance ≤ 600 ohm
12.3.5 Parameterization
12.3.5.1 Input / output images
Input image
The image comprises 3 slots (n, m, d ≙ start address):
Slot 1: Digital inputs (DI)
n+0 … n+8 (9 byte)
X222.P3 - .P10 are rapid inputs
Slot 2: 2 analog inputs (AI): m+0 … m+7 (8 byte)
Slot 3: Diagnostics: d+0 .. d+1
Table 12-53 Input image of digital inputs for the 1st I/O module (n=0)
Terminal Byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
X111
n+0 Pin10
DI 0.7
Pin9
DI 0.6
Pin8
DI 0.5
Pin7
DI 0.4
Pin6
DI 0.3
Pin5
DI 0.2
Pin4
DI 0.1
Pin3
DI 0.0
n+1 Pin18
DI 1.7
Pin17
DI 1.6
Pin16
DI 1.5
Pin15
DI 1.4
Pin14
DI 1.3
Pin13
DI 1.2
Pin12
DI 1.1
Pin11
DI 1.0
n+2 Pin26
DI 2.7
Pin25
DI 2.6
Pin24
DI 2.5
Pin23
DI 2.4
Pin22
DI 2.3
Pin21
DI 2.2
Pin20
DI 2.1
Pin19
DI 2.0
Connectable components
12.3 PP 72/48D PN 2/2A PN
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA 147