Note
The Ethernet interfaces have what is called autocrossing functionality, i.e. when required,
transmit and receive lines are switched over.
Position of the Ethernet interfaces
X120 P1 (PN/IE-OP)
X130 P1 (PN/IE-NET)
X127 P1 (PN/IE), on the lower side of the NCU
Figure 8-4 Ethernet ports
Cable speci󹪝cation
Table 8-10 Cable speci󹪝cation for X120, X130, and X127
Characteristic Version
Connector type RJ45 socket
Cable type Industrial Ethernet cable (as of CAT5)
Max. data transmission rate: 10/100/1000 Mbit/s
Max. cable length 100 m
Connecting
8.7 Use of Ethernet interfaces
NCU 1740
70 Equipment Manual, 10/2021, A5E51087503B AA