A.8 Information List
655
7SD5 Manual
C53000-G1176-C169-1
3215 Incompatible Firmware Versions
(Wrong Firmware)
Prot. Interface OUT ON * LED BO
3217 Prot Int 1: Own Datas received
(PI1 Data reflec)
Prot. Interface OUT ON
OFF
* LED BO
3218 Prot Int 2: Own Datas received
(PI2 Data reflec)
Prot. Interface OUT ON
OFF
* LED BO
3227 >Prot Int 1: Transmitter is
switched off (>PI1 light off)
Prot. Interface SP ON
OFF
**LEDBIBO
3228 >Prot Int 2: Transmitter is
switched off (>PI2 light off)
Prot. Interface SP ON
OFF
**LEDBIBO
3229 Prot Int 1: Reception of faulty data
(PI1 Data fault)
Prot. Interface OUT ON
OFF
* * LED BO 93 135 1 Yes
3230 Prot Int 1: Total receiption failure
(PI1 Datafailure)
Prot. Interface OUT ON
OFF
* * LED BO 93 136 1 Yes
3231 Prot Int 2: Reception of faulty data
(PI2 Data fault)
Prot. Interface OUT ON
OFF
* * LED BO 93 137 1 Yes
3232 Prot Int 2: Total receiption failure
(PI2 Datafailure)
Prot. Interface OUT ON
OFF
* * LED BO 93 138 1 Yes
3233 Device table has inconsistent
numbers (DT inconsistent)
Prot. Interface OUT ON
OFF
* LED BO
3234 Device tables are unequal (DT
unequal)
Prot. Interface OUT ON
OFF
* LED BO
3235 Differences between common
parameters (Par. different)
Prot. Interface OUT ON
OFF
* LED BO
3236 Different PI for transmit and
receive (PI1<->PI2 error)
Prot. Interface OUT ON
OFF
* LED BO
3239 Prot Int 1: Transmission delay too
high (PI1 TD alarm)
Prot. Interface OUT ON
OFF
* LED BO 93 139 1 Yes
3240 Prot Int 2: Transmission delay too
high (PI2 TD alarm)
Prot. Interface OUT ON
OFF
* LED BO 93 140 1 Yes
3243 Prot Int 1: Connected with relay
ID (PI1 with)
Prot. Interface VI ON
OFF
*
3244 Prot Int 2: Connected with relay
ID (PI2 with)
Prot. Interface VI ON
OFF
*
3245 > GPS failure from external
(>GPS failure)
Prot. Interface SP ON
OFF
**LEDBIBO
3247 GPS: local pulse loss (GPS loss) Prot. Interface OUT ON
OFF
**LEDBO
3248 GPS: Prot Int 1 is GPS sy-
chronized (PI 1 GPS sync.)
Prot. Interface OUT ON
OFF
**LEDBO
3249 GPS: Prot Int 2 is GPS sy-
chronized (PI 2 GPS sync.)
Prot. Interface OUT ON
OFF
**LEDBO
3250 GPS:PI1 unsym.propagation
delay too high (PI 1 PD unsym.)
Prot. Interface OUT ON
OFF
**LEDBO
3251 GPS:PI2 unsym.propagation
delay too high (PI 2 PD unsym.)
Prot. Interface OUT ON
OFF
**LEDBO
3252 > PI1 Synchronization RESET
(>SYNC PI1 RESET)
Prot. Interface SP on
off
**LEDBIBO
3253 > PI2 Synchronization RESET
(>SYNC PI2 RESET)
Prot. Interface SP on
off
**LEDBIBO
3254 Prot.1: Delay time change recog-
nized (PI1 jump)
Prot. Interface OUT on
off
**LEDBO
3255 Prot.2: Delay time change recog-
nized (PI2 jump)
Prot. Interface OUT on
off
**LEDBO
3256 Prot.1: Delay time unsymmetry to
large (PI1 unsym.)
Prot. Interface IntSP ON
OFF
* LED BO
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation
www . ElectricalPartManuals . com

Table of Contents

Other manuals for Siemens siprotec 7SD5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens siprotec 7SD5 and is the answer not in the manual?

Siemens siprotec 7SD5 Specifications

General IconGeneral
BrandSiemens
Modelsiprotec 7SD5
CategoryRelays
LanguageEnglish

Related product manuals