Safety notes
2.1 Laws and directives
SITRANS F M MAG 5100 W
8 Operating Instructions, 11/2010, A5E03063678-02
CE marked equipment
All meters carry either a CE mark or a CE mark followed by eg.200
CE200: This indicates that the product conforms to:
PED 97/23/EC
LVD 2006/95/EC
EMC 2004/108/EC
CE: This indicates that the product conforms to:
LVD 2006/95/EC
EMC 2004/108/EC
Compliance with PED directive
"Pressure Equipment Directive" (PED) is mandatory for all pressure equipment sold within
the EU and EFTA.
Siemens Flow Instruments products confirms to PED by following the tables below.
Table 2- 1 MAG 5100 W (7ME6580 only DN15 ... 600 (½" ... 24"))
Flange mm PN 10 PN 16 PN 40 150 lb 300 lb
15 N/A N/A SEP SEP N/A
25 N/A N/A SEP SEP N/A
40 N/A N/A SEP SEP N/A
50 N/A SEP N/A SEP N/A
65 N/A SEP N/A SEP N/A
80 N/A SEP N/A SEP N/A
100 SEP SEP N/A SEP N/A
125 N/A SEP N/A PED N/A
150 N/A PED N/A PED N/A
200 SEP PED N/A PED N/A
250 LVD PED N/A PED N/A
300 LVD PED N/A PED N/A
350 LVD PED N/A PED N/A
400 LVD PED N/A PED N/A
450 LVD PED N/A PED N/A
500 LVD PED N/A PED N/A
600 LVD PED N/A PED N/A
700 LVD PED* N/A N/A PED
750 N/A N/A N/A N/A PED