Technical data
8.3 Effect of temperature on working pressure
SITRANS F M MAG 5100 W
Operating Instructions, 11/2010, A5E03063678-02
41
Coil cable Standard electrode
cable
Media temperature:
< 100 °C 40 Ω N/A
Max. cable loop resistance
> 200 °C 6 Ω N/A
M20x1.5 gland - Cable ø 5 ... 13 mm (0.20 ... 0.51 inches) Cable glands on sensor
and transmitter
½ NPT gland - cable ø 5 ... 9 mm (0.20 ... 0.35 inches)
Special applications, e.g. low conductivity or electrical noise
Table 8- 7 Technical data, special application cables
Coil cable Special electrode cable
No. of conductors 3 3
Sqr. area 1.5 mm
2
0.25 mm
2
Shield Yes Double
Color code Brown, blue, black Brown, blue, black
Outside color Grey Grey
Ext. diameter 7.8 mm 8.1 mm
Conductor Flexible CU Flexible CU
Basic data
Isolation material PVC PVC
Flexible installation -5 ... +70°C
(23 ... 158°F)
-5 ... +70°C
(23 ... 158°F)
Ambient temperature
Non-flexible installtaion -30 ... +70°C
(-22 ... 158°F)
-30 ... +70°C
(-22 ... 158°F)
Capacity 161.50 pF/m N/A
Inductance 0.583 μH/m N/A
Cable parameter
L/R 43.83 þH/Ω N/A
8.3 Effect of temperature on working pressure
Effect of temperature on working pressure.
Table 8- 8 Metric measures (pressure in bar)
Temperature (°C)
Flange
specifications
Flange rating
-5 10 50 90
Sizes DN25 ... 2000
PN 10 10.0 10.0 9.7 9.4
PN 16 16.0 16.0 15.5 15.1
EN 1092-1
PN 40 40.0 40.0 38.7 37.7
ANSI B16.5 150 lb 19.7 19.7 19.3 18.0
AWWA C-207 Class D 10.3 10.3 10.3 10.3