Appendix
A.2 Factory settings
SITRANS F M MAG 5100 W
Operating Instructions, 11/2010, A5E03063678-02
53
Dimensions (mm) Bolting
mm D PCD T B Holes Bolts
AWWA
700 927 864 33 35 28 M33
750 984 914 35 35 28 M33
800 1060 978 38 41 28 M39
900 1168 1068 41 41 32 M39
1000 1289 1200 41 41 36 M39
1050 1346 1257 44 41 36 M39
1200 1511 1422 48 41 44 M39
A.2 Factory settings
Dimension-dependent factory settings
Table A- 2 50 Hz version
Qmax
DN
Order no. 7ME6520 Order no. 7ME6580
Unit Volume/
pulse
Pulse
unit
Totalizer
unit
mm Inch Fac
settings
Min. Max. Min. Max.
15 ½ 2000 159 6361 - - l/h 1 l l
25 1 5000 441 17671 441 17671 l/h 10 l l
40 12 1.1 45 1.1 45 m
3
/h 10 l l
50 2 20 1.7 63 1.7 70 m
3
/h 10 l l
65 30 2.9 100 2.9 119 m
3
/h 100 l l
80 3 50 4.0 160 4.5 180 m
3
/h 100 l l
100 4 120 6.2 250 7 282 m
3
/h 100 l l
125 5 180 10.0 400 11 441 m
3
/h 100 l m
3
150 6 250 15.7 629 15.9 636 m
3
/h 100 l m
3
200 8 400 24.9 997 28.2 1130 m
3
/h 1 m
3
m
3
250 10 700 40.0 1600 44.1 1767 m
3
/h 1 m
3
m
3
300 12 1000 62.5 2500 63.6 2544 m
3
/h 1 m
3
m
3
350 14 1200 86.5 3463 86.5 3463 m
3
/h 1 m
3
m
3
400 16 1800 113 4523 113 4523 m
3
/h 1 m
3
m
3
450 18 2000 143.1 5725 143.1 5725 m
3
/h 1 m
3
m
3
500 20 3000 176.7 7068 176.7 7068 m
3
/h 1 m
3
m
3
600 24 4000 254.4 10178 254.4 10178 m
3
/h 10 m
3
m
3
700 28 5000 346.3 13854 346.3 13854 m
3
/h 10 m
3
m
3
750 30 6000 397.6 15904 397.6 15904 m
3
/h 10 m
3
m
3
800 32 7000 452.3 18095 452.3 18095 m
3
/h 10 m