Technical data
8.1 MAG 5100 W
SITRANS F M MAG 5100 W
Operating Instructions, 11/2010, A5E03063678-02
39
Version MAG 5100W (7ME6520) MAG 5100W (7ME6580)
Process fluid temperature
NBR
-10 ... +70 °C (14 ... 158 °F) -
EPDM
-10 ... +70 °C (14 ... 158 °F) -
EPDM (MI-001)
+0.1 ... +30 °C (32 ... 76 °C) -
Ebonite
- -10 ... +70 °C (14 ... 158 °F)
EMC EMC 2004/108/EC EMC 2004/108/EC
Maximum operating pressure decreases with increasing operating temperature
Table 8- 4 Design
Version MAG 5100W (7ME6520) MAG 5100W (7ME6580)
Housing and flange material Carbon steel, with corrosion-resistant
two-component epoxy coating (min.
150 µm)
Corrosive category C4, according to
ISO 12944-2
Carbon steel ASTM A 105, with
corrosion-resistant two-component
epoxy coating (min. 150 µm)
Measuring pipe AISI 304 (1.4301) AISI 304 (1.4301)
Electrodes Hastelloy Hastelloy
Grounding electrodes (standard Hastelloy Hastelloy
Terminal box Fibre glass reinforced polyamide Fibre glass reinforced polyamide
Table 8- 5 Certificates and approvals
Version MAG 5100W (7ME6520) MAG 5100W (7ME6580)
Calibration
Standard production calibration,
calibration report shipped with sensor
DN 15 ... 300:
Zero-point, 2 x 25 % and 2 x 90 %
DN 350 ... 1200:
Zero-point, 1 x 25 % and 1 x 90 %
Zero-point, 2 x 25 % and 2 x 90 %
Custody transfer (only with MAG
5000/6000 CT)
OIML R 49 pattern approval cold water
(Denmark and Germany):
DN 50 ... 300 (2" ... 12")
MI 001 cold water (EU):
DN 50 ... 300 (2" ... 12")
-