EasyManua.ls Logo

Siemens Sitrans F Series - Page 235

Siemens Sitrans F Series
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Channel 3 discrete input settings
Table A-59 Channel 3 discrete input settings
Modbus
register
Data type /
Size in bytes
Parameter Description Default value
[units]
(units register)
Value range /
Setting options
Access
level
9131 Unsigned / 2 Input leading
edge function
Select the functionality
for the leading edge of
the active discrete in‐
put signal.
0
0: Off
6: Reset totalizer 1
7: Reset totalizer 2
8: Reset totalizer 3
9: Reset all totalizers
10: Start zero point
adjustment
11: Force outputs
12: Freeze process
values
13: Stop forcing
outputs
14: Unfreeze process
values
Read /
write
9132 Unsigned / 2 Input trailing
edge function
Select the functionality
for the trailing edge of
the active discrete in‐
put signal.
0
0: Off
6: Reset totalizer 1
7: Reset totalizer 2
8: Reset totalizer 3
9: Reset all totalizers
10: Start zero point
adjustment
11: Force outputs
12: Freeze process
values
13: Stop forcing
outputs
14: Unfreeze process
values
Read /
write
Modbus communication