F US Clamp-on Communications Module Installation
SITRANS F US Clamp-on Communications Module
16 Compact Hardware Installation Instructions, 2/2014, A5E32586525-AD
Note
When using the WEB utility there are parameters under View/Data Arrays/ that identify the
position of the DIP switches:
•
DA-DIP: All 16 positions of switches A & B are identified in decimal form
DA-DIP_A: All 8 positions of switch A are identified in decimal form
DA-DIP_B Positions 1-4 of switch B are identified in decimal form
DA-DIP_S Positions 5-8 of switch B are identified in decimal form
Note
Flow Meter Firmware Version
The flow meter firmware version is listed in the meter menu: Meter Facilities/Sy
stem/Op
Table 3- 1 Profile Selection: 1 - 46
Flow Meter Firmware Version & Configuration
5N01-5.04.05 CH1: Clamp-On
5N01-5.04.05 CH1: Reflexor
5N02-5.04.05 CH1: Clamp-On
On On Off Off Off Off profile 4 5N02-5.04.05 CH1: Reflexor
5N03-5.04.05 CH1: Clamp-On CH2: Clamp-On
On Off On Off Off Off profile 6 5N03-5.04.05 CH1: Reflexor CH2: Reflexor
5N03-5.04.05 CH1: Clamp_on CH2: Reflexor
5N03-5.04.05 DP: Clamp-On
5N03-5.04.05 CH1+2: Clamp-On
5N03-5.04.05 CH1-2: Clamp-On
5N04-5.04.05 CH1: Clamp-On CH2: Clamp-On
5N04-5.04.05 CH1: Reflexor CH2: Reflexor
5N04-5.04.05 CH1: Clamp-On CH2: Reflexor
5N04-5.04.05 DP: Clamp-On
5N04-5.04.05 CH1+2: Clamp-On
5N04-5.04.05 CH1-2: Clamp-On
5MN01-5.04.05 4 Channel Flow: Clamp-On
5MN01-5.04.05 CH5: Clamp-On
5MN01-5.04.05 Quad Path: Clamp-On
5MN02-5.04.05 4 Channel Flow: Clamp-On
5MN02-5.04.05 CH5: Clamp-On
5MN02-5.04.05 QP: Clamp-On
Off On On Off On Off profile 23 5EN02-5.04.05 Ch1: Clamp-On
5EN02-5.04.05 Ch1: Reflexor