SITRANS F US Clamp-on Communications Module
Compact Hardware Installation Instructions, 2/2014, A5E32586525-AD
9
F US Clamp-on Communications Module Installation
3
These Communications Module kit installation instructions address the three types of
installation procedures for the flow meter:
1. Flow meters purchased with the correct MLFB number that includes the Communications
Module will be supplied with the proper mounting kit and require no installation of the
Communications Module.
Refer to page 10 for installation procedure.
2.
Fielded flow meters with no previous Communications Module installed
.
Procedure requires installation of Communications Module with the necessary mounting
kit:
Mounting Kit
Meter Type
Meter Configuration
1015N-5M-MK1 1010N/DN
1010N-2 I/O Module with
1010N-5 Analog Input Module
installed
1010N-7 Expanded I/O Module
with 1010N-5 Analog Input
Module installed
1015N-5M-MK2 1010N/DN
1010N-2 I/O Module only
installed
1010N-7 Expanded I/O Module
only installed
1015N-5M-MK3 1010MN 1010N-8M I/O Module with
1010N-2M Module installed
3.
Fielded flow meters with existing Communications Module.
Required installation procedures include:
Removal of the existing communications module
Installation of Communications Module (no mounting kit necessary)