General IconGeneral
TypeRadar Level Transmitter
Frequency80 GHz
Process PressureUp to 3 bar
Output Signal4 to 20 mA
Output4 to 20 mA / HART
Communication ProtocolHART
CommunicationHART
Enclosure RatingIP68
Measuring PrincipleFMCW Radar
Measuring range0.08 to 30 m
Process Temperature-40 to +80 °C
Power Supply12 to 30 V DC
Housing MaterialAluminum

Summary

Preface

Safety instructions for Ex areas

Highlights specific safety precautions for explosive environments.

Safety notes

Authorised personnel

Specifies requirements for individuals operating the device.

Appropriate use

Defines the intended application and conditions for the transmitter.

Warning about incorrect use

Alerts users to hazards from misuse.

General safety instructions

Lists essential safety guidelines for operation.

Installingmounting

General instructions

Provides guidelines for ambient and process conditions.

Mounting instructions

Gives specific steps and considerations for installation.

Measurement setup - Flow

Explains how to configure the device for flow measurement.

Connecting

Preparing the connection

Details safety and requirements before electrical connection.

Wiring plan

Shows wire assignments for the connection cable.

Access protection

Setup with smart device (Bluetooth)

Diagnostics and troubleshooting

Rectify faults

Explains how to identify and fix malfunctions.

Diagnosis, fault messages

Details how to interpret error codes and messages.

Status messages according to NE 107

Describes device status indicators.

Service and maintenance

Technical data and dimensions

Technical data

Presents detailed specifications of the device.