Installing/mounting
4.4 Installation instructions
SITRANS LR250 with FOUNDATION FIELDBUS
26 Compact Operating Instructions, 09/2021, A5E48453221-AB
Flange bolting: recommended torque
Pressure class Nominal pipe size
(NPS)
Number of bolts Recommended torque
(Nm)
ASME B16.5, Class 150
2"
4
30 50
3"
50 70
4"
8
40 60
6"
70 90
EN1092-1, PN16 /
JIS B 2220, 10K
DN50/50A
4
30 50
DN80/80A
8
DN100/100A
DN150/150A
60 80
Flange bolting instructions:
1. Use cross-pattern sequence as shown.
2. Check uniformity of the flange gap.
3. Apply adjustments by selective tightening if required.
4. Torque incrementally until desired value is reached.
5. Check/re-torque after 4 to 6 hours.