Variable Note Type L Rw Default Min. Max.
Effective tare
weight - from
specification
(Page 72)
Current tare weight from
specification as process
value
REAL 4 rw 0 0 Depends
on specifi‐
cation in
DR 3
Effective tare
weight (semi-
automatic)
(Page 72)
Current tare weight from
semi-automatic mode as
process value
REAL 4 rw 0 0 Depends
on specifi‐
cation in
DR 3
Reserve Reserve REAL 4 rw 0 - -
Zero weight
(semi-automat‐
ic) (Page 72)
Current zeroing weight
(affected by zeroing)
REAL 4 rw 0 Depends
on specifi‐
cation in
DR 3
Depends
on specifi‐
cation in
DR 3
Current zero
tracking weight
(Page 73)
Zero point correction
weight affected by auto‐
matic zeroing
REAL 4 rw 0 Depends
on specifi‐
cation in
DR 3
Depends
on specifi‐
cation in
DR 3
Dead load
(Page 73)
Dead load determined
during calibration
REAL 4 r 0 Depends
on specifi‐
cation in
DR 3
Depends
on specifi‐
cation in
DR 3
Reserve 1 Reserve INT 2 rw 0 - -
Reserve 2 Reserve UINT 2 rw 0 - -
Reserve 3 Reserve REAL 4 rw 0 - -
8.7.1 Effective tare weight - from specification
A tare weight can be specified in data record DR 15. You activate the specified tare weight with
a command (see command 1013). From this point on, the activated tare weight is factored into
the weight calculations. The "Delete tare" command deactivates the active tare weight. This
does not delete the specification in data record DR 15.
8.7.2 Effective tare weight (semi-automatic)
The corresponding command (see command 1011) applies the current gross weight as the
active tare weight. From this point on, the activated tare weight is factored into the weight
calculations. The "Delete tare" command deactivates the active tare weight.
8.7.3 Zero weight (semi-automatic)
The zero weight command (see command 1001) entered by the user sets the current gross
weight to "Zero" provided it is within the defined zero setting limits. The current gross weight is
saved as the zero weight. The zeroing weight must be within the specified range (usually +3 /
‑1 % of the set zero point).
Scale parameters and functions
8.7 DR 5 zeroing memory
SIWAREX WP321
72 Operating Instructions, 08/2019, A5E33715669A-AD

Table of Contents

Other manuals for Siemens SIWAREX WP321

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP321 and is the answer not in the manual?

Siemens SIWAREX WP321 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP321
CategoryAccessories
LanguageEnglish

Related product manuals