MDP 101-1
05.06.2020 Page 21
General
Article number
09-403-101-1
Standard
UL 508C, NMMS.E336350
2.9 Safety conformity
Safety Integrity Level according to IEC EN 62061
SIL 3
Performance Level according to EN ISO 13849-1
PLe
Probability of failure per hour
PFH
D
[10
-9
]
0,3
Mean time to dangerous failure
MTTF
D
symmetrized [Years]
High
Proof Test Interval [Years]
20
2.10 Ambient conditions, ventilation and mounting
Storage conditions
page 68
Transport conditions
page 68
Ambient temperature in operation
0 to +45 °C (32 to 113 °F) at rated data
+45 to 55 °C (113 to 131 °F) with power derating of 2.5 % /
K
Humidity in operation
Relative humidity 85 %, no condensation
Site altitude
Up to 1000 m above sea level at rated data
1000 to 2500 m above sea level with derating of 1.5 % /
100 m
Pollution degree
2
Servo drive enclosure protection class
IP 20
Mounting position
page 29
Ventilation
Forced ventilation by controlled internal fan
2.11 Auxiliary Power Supply
The power supply that is used for the +24 V auxiliary power supply voltage and the holding
brake supply (+24 V-BR) must be a power supply with a galvanically isolated SELV output
voltage according to EN60950. Due to the inrush current of the drive during switch-on, the
current rating must be at least 5 A.