34
TROUBLESHOOTING, Continued
#9 SYMPTOM: Double welding. Immediately after completing cycle machine goes into another weld
cycle.
CAUSE REMEDY
Drop-out arm (159) is stuck in open position. Make sure drop-out arm is free and its pivot pin is
lightly lubricated. Do not
get lubricant on tension
wheel (170).
#10 SYMPTOM: Strap escapes from stretch-out box during take-up.
CAUSE REMEDY
1. Too much strap being taken up.
2. Strap does not accumulate in stretch-out box.
1. Check package to chute ratio. Ratio should not
exceed 5:1.
2. Strap is too stiff, add strap snubber kit
#185298 to stretch-out box.
#11 SYMPTOM: Low or erratic tension.
CAUSE REMEDY
Slip clutch set too high. Adjust slip clutch nut (54).
For Parts & Service 1-877-862-6699