Appendix-3
▼ Basic specifications
Appendix
(2/2)
Items
Specifications/Function
LP-1010 LP-1010L
Noise
In operation : 61dB (A) or less (continuous sound)
In standby : 53dB (A) or less
Calorific value 4700 kJ or less
Power supply voltage 100 V AC ± 10%
Frequency 50/60 Hz ± 1Hz
Power consumption
In operation : 1440 W or less
In standby : 60 W or less (in Power Save mode)
External dimensions
1150 (W) × 552 (D) × 1063 (H) mm
45.3 (W) × 21.7 (D) × 41.9 (H) inches
Weight 190 kg or less
Temperature/humidity
range in use of plotter
15 to 35˚ C/20 to 80%RH (no dew condensing)
Humidity should be 48% or less when temperature is 35˚ C, or
temperature should be 28˚ C or less when humidity is 80%RH.
Temperature/humidity
range in nonuse of plotter
-5 to 40˚ C/10 to 90%RH (no dew condensing)
Installation space
1760 (W) × 1650 (D) × 1500 (H) mm
69.3 (W) × 65.0 (D) × 59.1 (H) inches
Maintenance space
2560 (W) × 2050 (D) × 2000 (H) mm
100.8 (W) × 80.7 (D) × 78.7 (H) inches