UNOCODE 299 Operating manual - English
28 Copyright Silca 2002
- the operational sequence will continue
and the display will show the settings
for sides B, C and D.
• turn the V100 clamp to side B, insert the (Z3)
template into the clamp and proceed with the
settings, following the same procedure
described for side A.
• turn the V100 clamp to side C, insert the (Z3)
template into the clamp and proceed with the
settings, following the same procedure
described for side A.
ATTENTION: make sure that the (Z3) template is properly
inserted into side C of the V100 clamp (see
fig. 23).
• turn the V100 clamp to side D, insert the (Z3)
template into the clamp and proceed with the
settings, following the same procedure
described for side A.
ATTENTION: make sure that the (Z3) template is properly
inserted into side D of the V100 clamp (see
fig. 23).
Operational keys:
use the arrow keys to directly select the side of the clamp
you intend to set.
START: to begin the setting procedure.
STOP: to interrupt the setting procedure.
ATTENTION: after calibrating all sides of the V100 clamp:
- remove the (Z3) template from the V100
clamp.
- remove the (Z1) template from the cutter
shaft replacing it with a cutter.
Fig. 23
V100 SIDE B
Adjustment SIDE B
X = +00 Y = +00
To calibrate [START]
V100 SIDE C
Adjustment SIDE C
X = +00 Y = +00
To calibrate [START]
V100 SIDE D
Adjustment SIDE D
X = +00 Y = +00
To calibrate [START]
side
C
side
D
Z3
Z3