EasyManua.ls Logo

SilentWind MPPT HYBRID BOOST CHARGE CONTROLLER - Technical Data; Electrical Data; Mechanical Data; Installation Notes

SilentWind MPPT HYBRID BOOST CHARGE CONTROLLER
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MPPT Charge Controller User Manual - Feb. 2019 8
3. TECHNICAL DATA
3.1 MPPT HYBRID BOOST CHARGE CONTROLLER ELECTRICAL DATA
System voltage
12 VDC / 24 VDC / 48 VDC
Max. power input wind generator
600 Watt
Max. current input of the wind generator
40 A / 30 A / 15 A
Max. power input solar
300 Watt
Max. current input solar
20 A / 10 A / 5 A
Max. open circuit voltage input of the solar panel
48 VDC / 48 VDC / 96 VDC
Max. total charge current
60 A
Max. switch off current at LOAD-output (Load)
2 x 10 A
Max. voltage adjustable for the battery types
Acid, Gel, AGM and Lithium
LCD + LED displays
W, A, V, Ah
3.2 MPPT HYBRID BOOST CHARGE CONTROLLER - MECHANICAL DATA
Weight
2.30 kg
Package dimensions
220 x 150 x 83 mm
Cover protection class
IP52
3.3 INSTALATION NOTES
The machine should be kept indoors and well ventilated
Environment temperature
-20 ˚C - +40 ˚C
Altitude
< 1000 m
The space around the device has no other items within
30cm
Can only charge batteries in the same rated voltage range
The charge controller can only be connected to the wind turbine and the PV in the
same rated voltage range