Values
12V
24V
48V
End of charge voltage
14,4V
28,8V
57,6V
Overvoltage
16V
32V
64V
Low Wind Boost
3V
4V
10V
Storm Brake
32A
16A
9A
Under Voltage Switch Off
10,8V
21,6V
43,2V
Under Voltage Recovery On
12V
24V
48V
Solar Switch Off
1,5V
3V
6V
Solar Switch On
1V
2V
3V
The above table is for standard GEL and AGM batteries. Costumers must always check
the battery manufacturer settings recommendations.
The End of Charge Voltage is critical.
The Storm Brake is critical.
Silentwind cannot be held responsible for bad parameter settings that might permanently damage
your batteries, your charge controller and your wind generator.
If you need to change the parameters, it can be done directly on the Hybrid Boost Charge Controller
or through APP.
5.7.1 SCAN BUTTON
How the SCAN button works:
Press momentarily to change between screens
Press for 2s to enter SET mode (LCD shows “SET”, settings will vary according to the screen),
pressing again for 2s will exit and save the SET mode
Pressing the scan button on SET mode will adjust the parameters
Press de button for 5s to turn the Brake On
Press the button for 8s to fix the voltage degree, and then you can enter the setting
interface after it shows “24” or “12”. (Not recommended, leave it as it is)
Press the button for 10s to reset to factory defaults and the 8888 number will be displayed
on the LCD. Stop pressing the button and then click it momentarily to turn the charge
controller to normal operation.
The value is looped through several parameters. So, if the value you want to set is less than
the one it showed on the LCD at present, you just need increase it and let it back to the
small value you need.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SilentWind MPPT HYBRID BOOST CHARGE CONTROLLER and is the answer not in the manual?

SilentWind MPPT HYBRID BOOST CHARGE CONTROLLER Specifications

General IconGeneral
BrandSilentWind
ModelMPPT HYBRID BOOST CHARGE CONTROLLER
CategoryController
LanguageEnglish