‘‘Blend” key will only appear systematically. Activating this key will switch modality from “Thermolysis” to “Blend”.
When blend is selected, an extra “Electrolysis” dial will appear which can be used to modify galvanic parameters.
Pressing the “Thermo” key will switch back to Thermolysis mode.
The hair selection bar displays the selected hair. The blue lines represent a graphic of the power output. To select a
different hair size while working in the same area, simply press this bar key, the hair selection icons will appear.
‘‘Home” icon at the bottom of the Depilation treatment, is a shortcut which allows going back to the start menu in
order to access to the next treatment, Soothing phase.
By pressing this icon, you reset the time to 0 without having to go back into the key.
By pressing this icon you stop or restart the treatment time.
B – Selection by hair size;
Same settings as in preprogrammed parameters, only the treatment zone does not appear.
C – Manual Mode;
You have the possibility of working by choice of hair removal technique (without hair gauge or treatment area) and you
let the parameters change according to your free interpretation:
1. In Thermolysis only mode, the parameters are zero. Select the ‘‘Therm’’ key.
2. In Electrolysis only mode, the parameters indicate by default a time for the wave to pass.
Select the ‘‘Elec’’ key.
3. In Blend mode, a basic parameter is proposed to you in order to start the treatment freely. Select the ‘‘Blend’’
button.