EasyManuals Logo

Silva ADC Pro User Manual

Silva ADC Pro
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
Humidity Mode
HUMIDITY
44.0 62.288CC
88.2%
H.INX 50.2 C8
Relative Humidity Mode - Functional Display15.0
Heat Index
mode indicator
Relative Humidity
Wet Bulb
Temperature
Dew Point
Temperature
F
Relative Humidity Mode includes four different
readings; Heat Index Temperature, Relative
Humidity, Dew Point Temperature and Wet
Bulb Temperature.
In the above displays, the indicator ' '
appears on the 1st row of the display.
The Heat Index Temperature appears on the
2nd row of the display.
The Relative Humidity appears on the 3rd row
of the display.
The Dew Point Temperature and Wet Buld
Temperature appear on the 4th row of the
display.
unctional Displays
!
!
!
!
!
HUMIDITY
To Change Temperature Unit
!
!
The above temperature readings can be
display in the following units:
1) Degree Celsius (ºC)
2) Degree Fahrenheit (ºF)
Set the temperature unit in the Temperature
Mode to change the temperature unit. Check
the previous ' ' section
for more detail on how to change the
temperature unit.
Temperature Display
Wet-bulb:
The evaporation of water from the thermometer with
the bulb wrapped in wet cloth has a cooling effect.
The temperature indicated by the wet bulb
thermometer is less than the temperature indicated
by a normal thermometer. The rate of evaporation
from the wet-bulb thermometer depends on the
humidity of the air - evaporation is slower when the
air is already full of water vapor.

Table of Contents

Other manuals for Silva ADC Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Silva ADC Pro and is the answer not in the manual?

Silva ADC Pro Specifications

General IconGeneral
BrandSilva
ModelADC Pro
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals