27
Figure 15: Power on Timing Sequence
Table 5: Power on timing
Parameter Description
Time value
Unit
Min. Typ. Max.
Ton The time to pull POWER_ON down to power on 64 180 - ms
TpD+ The time to indicate connecting with the network - - 5.5 s
Tpw+
The time to indicate the module is powered on
completely
-
-
4.5 s
Tuart The time to enable UART - - 5 s