Smart Machine Smart Decision
SIM7600V-H_User Manual_V1.00 2018-02-24
Note: The sinking current can be adjusted to meet the design requirement through the AT
command “AT+ CLEDITST =<0>, <value>”.The “value” ranges from 0 to 8, on behalf of the
current from 0mA to 40mA by 5mA step.
Module has 1 dedicated ADC pins named ADC. They are available fordigitizing analog signals
such as battery voltage and so on. These electronic specifications are shown in the following table.
Table 20: ADC Electronic Characteristics
Note: “AT+CADC” can be used to read the voltage of the ADC pins, for more details, please
refer to document [1].