4
WARNINGS
– Incaseoffaultand/orincorrectequipmentoperation,deactivateit,withoutmakinganyrepairsortakinganydirectaction.Apply
onlytoqualifiedtechnicalpersonnel.
– Boilerinstallationandanyotherassistanceand/ormaintenanceactivitymustbecarriedoutbyqualifiedpersonnelpersuantto
StandardCEI64-8.Undernocircumstances,thedevicessealedbythemanufacturercanbetamperedwith.
– Itisabsolutelyprohibitedtoblocktheintakegrillesandtheaerationopeningoftheroomwheretheequipmentisinstalled.
– Themanufacturershallnotbeheldliableforanydamagecausedbyimproperuseoftheappliance.
– Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,or
lackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebya
personresponsiblefortheirsafety.Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
LIGHTING AND OPERATION
BOILER IGNITION (fig.1)
Thefirstignitionoftheboilermustbe
carriedoutbyqualifiedtechnicalper-
sonnel.
Successively,ifitisnecessarytostart
upthe boileragain,adherestrictlyto
the following instructions: open the
gastaptoallowtheflowofthefueland
movethemainswitchofthesystemto
“ON”. After a stop, wait for about 30
seconds before restoring functioning
conditionsso thatthe boilercan per-
formthecontrolsequence.
Ifthegreenledison,thisindicatesthe
presenceofvoltage.
Winter
Pressthekey
1
2
3
4
ofthecontrolstoac-
tivatethewintermodefunctioning(he-
atingandD.H.W.).Thedisplaywillbe
asshowninthefigure.
Summer
(not applicable to this boiler version)
Pressthekey
1
2
3
4
ofthecontrolstoac-
tivate the summer mode functioning
(only the production D.H.W.). The di-
splaywillbeasshowninthefigure.
1
2
3
4
Fig.1
ATTENTION: Usethekeystoalterthevaluesofanyfunction,abeepindicatesthata
keywastouchedandthefunctionactivated.after15minutesthedisplaywillturnoff
(PAR5default).
1
2
3
4
1
2
3
4
KEYS LOCK: ifthedeviceisnotused,thekeyswillbelocked15minutesafterthelastsettingwasmade(PAR
5bydefault)andthedisplaylightswitchesoff.
Tosetoneoftheoperatingmodes,pressanyofthekeysformorethantwoseconds(thedisplaywillindicate
onetofoursegmentsprogressivelybeforeunlockingthecontrols).
1.0 USERS INSTRUCTIONS