Note.
To complete the software configuration update procedure for a digital DMR system,
the system must be rebooted; while for an individual base, the base must be
rebooted.
26. To reboot a complete system, carry out the following:
a. On the System I/O page, in the System Monitor area, on the navigation
tree, right click on the VAC for the system. Menu options will be
displayed.
b. From the VAC menu options, select ‘Base Operations> ‘Reboot Base(s)
option. The ‘Reboot Baseswarning message will be displayed.
c. On the Reboot Bases warning message, select ‘Yes’ to continue.
d. In the Comms History area, confirm that a Starting Resetting VAC’
message is displayed and, after a short delay, confirm that a Completed
Resetting VAC’ message is displayed.
e. The Reboot operation of all the bases relevant to the system will now
take place.
27. To reboot an individual base, carry out the following:
a. On the System I/O page, in the System Monitor area, on the navigation
tree, right click on the base that you have written the configuration to.
Menu options will be displayed.
b. From the menu options, select ‘Base Operations> ‘Reboot Base(s)
option. The ‘Reboot Baseswarning message will be displayed.
c. On the Reboot Bases warning message, select ‘Yes’ to continue.
d. In the Comms History area, confirm that a Starting Resetting Base’
message is displayed and, after a short delay, confirm that a Completed
Resetting Base’ message is displayed.
e. The Reboot operation of the relevant base station will now take place.
Enable Bases
28. On the System I/O page, in the System Monitor area, on the navigation tree,
carry out the following:
a. To enable all the bases on a system, carry out the following:
i. Right click on the VAC that you wish to enable. Menu options will be
displayed.
ii. From the menu options, select ‘Site Options> ‘Enable Site(s)’. The sites
enable warning message will be displayed.
b. To enable an individual base, carry out the following:
i. Right click on the Base that you wish to enable. Menu options will be
displayed.
ii. From the menu options, select ‘Base Operations> ‘Enable Base(s). The base
enable warning message will be displayed.
Doc Number: TNM-I-E-0041 Revision 1.6 Page 46

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simoco SDB670 and is the answer not in the manual?

Simoco SDB670 Specifications

General IconGeneral
BrandSimoco
ModelSDB670
CategoryAccessories
LanguageEnglish

Related product manuals