Specications | AP70/AP80 Installation manual
AP70 and AP80 Control units
AP70 AP80
DISPLAY
Size 5 in\127 mm
Resolution (HxW) 480x480
Type 16-bit color TFT
Antifog bonded
Best viewing direction any direction
Backlight Cold Cathode Fluorescent Lamp (CCFL)
NETWORKING
CAN bus x
USB N/A x
Ethernet for sw update
POWER
Local supply 12/24 V DC +30-10%
Consumption local supply 0.7/0.4 A at 12 V DC 0.4/0.3 A at 24 V DC
backlight full/off"
NMEA 2000 Load Equivalent
number (50 mA)
1
INTERFACE External alarm/Active unit output max 100 mA, 4.5 A short
circuit limit
External Take CMD input, contact current max 8 mA
ENVIRONMENT
Temperature, operation -30°C to +55°C (-22°F to 131°F)
Temperature, storage -25°C to +70°C (-13°F to 158°F)
Protection IPx4 IPx6
MECHANICAL
Weight 1,2 kg (2.7 lbs) 1,4 kg (3.1 lbs)
Size Refer “Drawings” on page 79
Mounting Panel (flush) or optional bracket
Compass safe distance 0.4 m
Material Plastic Epoxy coated seawater
resistant aluminium, plastic
front bezel
Color Black and grey
Cable inlet, refer AP70 and
AP80 Connector pinouts” on
page 77
1 Power/alarm, 1 Micro-C con.