Loading...
SimNet network, small system
SimNet network, small system with Wind transducer
12V supply
Ter mination
not required
Tee Joiner
Tee Joiner
12V supply
* The supply cable and wind transducer have a built-in terminator.
*
*
* The supply cable has a built-in terminator.
CX33
CX33
CX34/44/54 NavStation Installation 1 - 19
SimNet power and termination
The following simple rules should be observed when installing SimNet:
• SimNet must be powered with 12 VDC and connected to the battery via
circuit breaker and 5 amp fuse.
• Do not connect the SimNet power cable to the same terminals as the
Autopilot Computer, Radar, thruster or other high current products.
• SimNet should normally be terminated in each end, starting with the power
cable with termination in one end and termination plug or wind transducer
(with termination) in the other end.