PAGE | 29
RJ45 crimping tool and wire as follows:
Pin Wire color
1
2 Orange
3
4 Blue
5
6 Green
7
8 Brown
If you need to test the 14-pin connector on the interconnection cable, it is wired as follows:
Pins on pedestal
Pins on cable
Pin Wire color
1 Pedestal power DC (-)
2 Red Pedestal power DC (+)
3 Yellow
4 Drain Tinned wire
5 Orange Pedestal power DC (+)
6 Blue RJ45 pin 4
7 RJ45 pin 5
8 RJ45 pin 7
9 Brown RJ45 pin 8
10 RJ45 pin 3
11 Blue Pedestal power DC (-)
12 RJ45 pin 1
13 Green RJ45 pin 6
14 Orange RJ45 pin 2
Connect the power cable
The power supply for the radar is connected to the RI-50 interface module. Depending on radar
24 V DC power systems.
The RI-50 is protected against reverse polarity, over-voltage and under-voltage. The RI-50 must be
Voltage Cable length
0-2 m
(0-6.6 ft)
2-3 m
(6.6-9.8 ft)
3-5 m
(9.8-16.4 ft)
5-7.5 m
(16.4-24.6 ft)
7.5-12 m
(24.6-39.4 ft)
12 V DC 4 mm
2
(12-AWG)
6 mm
2
(10-AWG)
10 mm
2
(8-AWG)
16 mm
2
(6-AWG)
25 mm
2
(4-AWG)
24 V DC
1.5 mm
2
(16-AWG)
1.5 mm
2
(16-AWG)
2.5 mm
2
(14-AWG)
4 mm
2
(12-AWG)
6 mm
2
(10-AWG)
¼ Notes:
• Above values in mm
2
= area of copper conductor. Stranded core cables are recommended.
• Conductor sizes greater than 10 mm
2
(8-AWG) require a short length of thinner cable (6 mm
2
10-AWG) to connect into the RI-50 screw terminals.