VDR Watchdog
ALARM BOX SENSOR CONFIGURATION
In alarm Box sensor panel,
There is one new setting -
"output mask
DEADMAN".
It sets up which pins should be pulsed wh
en
Application Manager sends message that
mouse or Keyboard were used since last check.
(32 in example give the function to the 6th led)
Normally pulse takes 2 seconds but you can
change this length ( Keep ACK mask sec )
option. (here is 5 seconds)
VDR WATCHDOG
INSTALLATION
VDR watchdog requires Application Manager and a VDR module which is running as a service
(VdrMon) on the VDR Computer.
Copy vdrmon.exe into VDR program folder
Copy vdrmon.ini into VDR program folder
Command “run vdrmon.exe ia”
Start Service with command line -s or via MMC
The service broadcasts the notifications immediately when VDR changes the currently-writing
file on the alternative data storage (normally, root folder of D: drive). Usually this happens
once per hour but if the crew wants to have this check more often they could reduce
timeframe length in VDR Configuration Manager.
CONFIGURATION IN APPLICATION MANAGER
The settings in Application Manager are simple and located in the same window than
Deadman Alarm Settings: