Operational limits
window in
SMonitor and
check the
incoming data
format.
Select another
format (NMEA
or..) ij the
configuration
window of the
serial port
Check
the output
configuration of
the GPS.
Click right button
in the GPS
indicator and
select GPS1 as
master.
Serial ports.
Serial cables
Sensor output set
up.
S_Monitor
configurations
C1
Other data
acquisition faulty
in SMonitor
Bad connection
with the se
nsor.
Sensor failure.
Bad selected data
format.
Data not correctly
acquired. No
display.
See above.
Serial ports.
Ethernet com.
Serial cables
Sensor output set
up.
S_Monitor
configurations
Second GPS
position not
correctly acquired
in the Monitoring
station.
Same on Planning
Station.
GPS2 failure.
Bad Ethernet
connection.
Second ship’s
position not
available (No
cross icon
displayed on the
chart at the
second GPS
location).
Check the cabling.
(Serial and
Ethernet).
Ethernet problem:
see above S1 and
S2.
OPERATIONAL LIMITS
OVERSCALING CHARTS
The accuracy of the overscaled charts is not as good as it should be for a safe navigation.
OUTPUT DATUM SELECTION FOR THE GPS
When the GPS sensor does not deliver on serial line information about the datum used for the
positioning, ECDIS900 supposes that the datum in use is WGS84. Therefore it is required to
select the datum WGS84 in the GPS sensor.
S57 LIMITED COVERAGE
S57 database coverage is still limited therefore ARCS must be used when no vector data are
available.