EasyManua.ls Logo

Sinoboom 1323RE - Page 17

Sinoboom 1323RE
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MACHINE SPECIFICATIONS
1323RE&1623RE Operation Manual 1-5 © Jun. 2021
Table 1-2 1623RE specifications (continued)
MEASURE
1623RE (METRIC) 5389RE (IMPERIAL)
Max. allowable altitude 1000m 3280.8ft
Allowable ambient temperature
(lead-acid batteries)
-10℃~40 14℉~104
Allowable ambient temperature (-
lithium batteries)
-20℃~40 -4℉~104
Max. allowable ambient relative
humidity
90%
Storage conditions
Stored at -20 to 50 (-4 to 122) in a well-ventilated environment
with 90% relative humidity (20 [68]), and away from rain, sun,
corrosive gas, inflammables and explosives.
WEIGHT
Total weight 9250 kg
20393 lb
NOTE:
a) The platform height plus the operator height (2m/6 ft 7in) is the working height.
b) In different areas, hydraulic oil, engine oil, coolant, fuel and lubrication should be added in accordance with the
environmental temperature.
c) In cold weather, auxiliary devices are needed to start the machines.
d) The ground bearing data is approximate, not considering different options and only applicable when it is safe
enough.
e) The loads of persons, accessories, tools and materials are factored into the rated platform capacity.
f) The total vibration value of the platform does not exceed 2.5m/s², and the maximum root-mean-square value of
the weighted acceleration of the entire machine does not exceed 0.5m/s².
g) The hydraulic tank capacity is the maximum volume in the hydraulic tank.