REPAIR PROCEDURES
AB18EJ&18HJ Maintenance Manual 6-21 © Oct 2020
Fault
code
Description
Cause Check
0215
Low temperature of FR
motor controller
0315
Low temperature of RL
motor controller
0415
Low temperature of RR
motor controller
0016
High temperature of pump
motor controller
1. Controller temperature
over 95;
2. Machine overload and
motor mismatch;
3. Controller damage.
1. Check the cooling measures of controller;
2. Monitor the operating current of controller,
re-match the motor if too large, reset the
turning point and slip valueproperly
restrict the current if needed.
3. If the above checks fail, replace the
controller.
0116
High temperature of FL
motor controller
0216
High temperature of FR
motor controller
0316
High temperature of RL
motor controller
0416
High temperature of RR
motor controller
0017
Severe undervoltage of
pump motor controller
1. Battery data setup
error;
2. Excessive battery
resistance;
3. Damaged fuse;
4. Damaged main
contactor.
1. Measure the battery voltage with a
multimeter to check proper voltage with
KSI and B+ circuits;
2. Check the fuse and contactor;
3. Check the battery setup, system voltage
and undervoltage setting.
4. If the drive controller fails, main contactor
not engaged, the pump controller will
report the fault.
0117
Severe undervoltage of FL
motor controller
0217
Severe undervoltage of FR
motor controller
0317
Severe undervoltage of RL
motor controller
0417
Severe undervoltage of RR
motor controller
0018
Severe overvoltage of
pump motor controller
1. Battery setup error;
2. Excessive battery
resistance;
3. Battery is disconected
when regenerative
brake enagages.
1. Check the battery with a multimeter for
proper voltage;
2. Check the fuse and contactor;
3. Check the battery setup, system voltage
and undervoltage setting.
4. Check the regenerative brake setup and
current limit.
0118
Severe overvoltage of FL
motor controller
0218
Severe overvoltage of FR
motor controller
0318
Severe overvoltage of RL
motor controller
0418
Severe overvoltage of RR
motor controller
0021
Reduced low-temperature
performance of pump
motor controller
The machine operates at
ambient temperatures
below -25
Use the machine under normal operating
conditions.
0121
Reduced low-temperature
performance of FL motor
controller
0221
Reduced low-temperature
performance of FR motor
controller