© Mar. 2022 1-2 GTJZ0612E&0812E&1012E&1212E Operation Manual
PERFORMANCE PARAMETERS
Table 1-1 GTJZ0612E Specifications (continued)
MEASURE
0612E (METRIC) 2146E (IMPERIAL)
Max. allowable manual force (indoor/
outdoor)
400N 90 lbf
Max. noise 72dB
POWER PARAMETERS
Drive×Steer 2 WD×2 WS
Power unit motor (voltage/power)
24V DC ,3.3 kW
Hydraulic tank capacity
15L
3.3 gal (imperial)/4 gal (US)
Hydraulic system pressure
21MPa 3046 Psi
Battery specification ( voltage, capacity,
rate of discharge)-lead-acid battery
24 V,220 Ah,20 hr
Battery specification (voltage, capacity,
rate of discharge)-lithium battery
25.6 V,200 Ah,1 hr
Power system voltage
24VDC
System control voltage
24VDC
Charger (input voltage/output current)
100~240 V AC/30 A
Drive motor (voltage/power)
24 V /0.85 kW
GROUND BEARING DATA
Max wheel load
1180 kg
2601 lb
Pressure against ground
1255 KPa 182 Psi
ENVIRONMENTAL REQUIREMENT
Max. allowable wind speed (indoor/
outdoor)
0 m/s/12.5 m/s
0 mph/28mph
Max. allowable altitude 1000m 3281ft
Allowable ambient temperature (lead-acid
batteries)
-10℃ to 40℃ 14℉ to 104℉
Allowable ambient temperature (lithium
batteries)
-20℃ to 40℃ -4℉ to 104℉
Max. allowable ambient relative humidity
90%
Storage condition
Stored at -20℃ to 50℃ (-4℉ to 122℉) in a well-ventilated environ-
ment with 90% relative humidity (20℃ [68℉]), and away from rain,
sun, corrosive gas and inflammables and explosives.
WEIGHT
Weight (in a no-load state) (indoor/
outdoor)
2455kg
5412 lb