13
Indicators above the function button
Status
Meaning
Indicator 1 is lit
Channel 1 is selected for display. Lubrication interval for
channel 1.
Indicator 2 is lit
Channel 2 is selected for display. Lubrication interval for
channel 2.
Indicators 1 and P are lit
Lubrication is in progress in channel 1. Channel 1 is being
pressurised.
Indicators 2 and P are lit
Lubrication is in progress in channel 2. Channel 2 is being
pressurised.
Indicator 1 is flashing
Pulse alarm in channel 1.
Indicator 2 is flashing
Pulse alarm in channel 2.
Indicator 1 is lit and P is
flashing
Reservoir low level alarm. Channel 1 is selected for display.
Indicator 2 is lit and P is
flashing
Reservoir low level alarm. Channel 2 is selected for display.
Indicator 1 or 2 flashes or is
switched off for a moment (50
ms)

Pulse signal received from the sensor.
None of the indicators are lit
See the troubleshooting table.
All indicators are lit
See the troubleshooting table.
Indicators 1, 2 and P are
flashing in alternately
See the troubleshooting table.
- 1, 2 or P - is always lit.