32 User Manual
DOL 534 • DOL 539
In two-zone houses, humidity control can be activated separately in each
zone.
Climate/ Humidity
Humidity
Setting of upper air humidity limit. See section 3.3.2.
Humidification
Setting of lower air humidity limit. See section 3.3.1.
Humidification last
day
Setting of the day number when DOL 53X deactivates humidification.
DOL 53X thus humidifies only at the start of the batch, until the natural humidity level
in the house has reached the desired level.
Current humidity
Current humidity level.
Humidity ventilation
Display of just how much is being ventilated due to humidity.
Min. humidity 24 h
The lowest humidity during the last 24 hours and the time it occurred.
Max.humidity 24 h
The highest humidity during the last 24 hours and the time it occurred.
Humidification
requirement
Current humidification requirement.
Active
Connecting and disconnecting humidity control. See section 3.3.2.
Humidity control
mode
Selecting type of humidity control. See section 3.3.2.1, 3.3.2.2 and 3.3.2.3.
Max. humidity
ventilation
In the case of humidity ventilation. Setting of the degree of ventilation where the
humidity ventilation stops.