56 User Manual
DOL 534 • DOL 539
3.11 Pressure Control
This section is relevant only to houses with active pressure control.
Main menu
Climate
Pressure
Pressure sensor
Setpoints
Pressure setpoint
Active in side mode
Yes/No
Active in tunnel mode
Yes/No
Info
Pressure control stopped
Calculated air inlet
Table 8: Overview of the complete Pressure menu at service user level.
By means of a pressure sensor, the DOL 53X can control the pressure level in the house. On the basis of the
sensor measurements, DOL 53X controls the opening of the flaps; this way, it maintains the required pressure
level in the house (Pressure setpoint).
Climate/ Pressure
Pressure setpoint
Setting of the pressure level.
Active in side mode
Connection and disconnection of pressure control in side ventilation.
Active in tunnel
mode
Connection and disconnection of pressure control in tunnel ventilation.
Pressure sensor
The current pressure level in the house.
Calculated air inlet
An indication (percentage) of how much the flaps are to be open to maintain the
Pressure setpoint.