User Manual 55
DOL 534 • DOL 539
Humidity to stop
tunnel cooling
The air humidity percentage that makes DOL 53X stop the tunnel cooling function.
When running at 10% or less the tunnel cooling is gradually reduced before being
stopped. Furthermore, a humidity limit can be set for the side cooling.
Bleed off active
Connection and disconnection of pad cleaning.
Time for bleed off
(Pad rinsing)
The time when the drainage function starts after tunnel cooling has run for a set
interval (Running time between drainage intervals).
Drainage does not start while tunnel ventilation is active.
Cooling blocked by:
In order to ensure that the cooling system does not run under inappropriate conditions
(not desirable due to the well-being of the birds), DOL 53X will stop the cooling even
though the inside temperature is high.
Runtime since last
bleed off
(Pad rinsing)
Reading of the time tunnel cooling has been running since the last drainage process.
Total runtime
Reading of total drainage running time. Can be used as an indicator of whether
cooling pads need to be replaced.
Tunnel cooling
requirement
Display of the current cooling requirement at Tunnel ventilation.
Tunnel cooling
temperature
Reading of the temperature that the tunnel cooling is controlled by when a dedicated
tunnel cooling sensor is used.
Number of starts
yesterday
Reading of how many times the cooling has been started yesterday.
Start based on:
Selecting which factor is to activate tunnel cooling. (Temperature/ Air speed).