82 User Manual
DOL 534 • DOL 539
Example 29: Alarm for Absolute high temperature - poultry
Temperature °C
Abs. high temperature
Set temperature
Day
Alarm for Absolute high temperature is released when the inside temperature exceeds the set value. The value
can be set as a curve over a time span of eight day numbers.
Example 30: All temperature alarms
High temperature summer 20/30 °C 8/4
Absolute high temperature
High temp. 4 °C
Temperature setpoint
Heat temp.
Low temp.
Outdoor temperature °C
The high temperature alarm adjusts for comfort temperatures so that the alarm does not generate until the
Comfort temperature has been added to the Temperature setpoint set.
24
30
35
40
20
18
16
0-5 10 15 20 25 30 35 405
Temperature range where the alarm is generated
Temperature range where the alarm is generated