29
SJ30 AJE SJ30 ARJE 213213AAA
Features and Devices Section 3 – Familiarization
WARNING
If the platform load sensing system is in fault mode
(overload light ashes), do the following:
▪
Ensure platform is level and there are no
obstructions contacting the platform.
If the platform load sensing system remains in
fault mode, the emergency power unit may be
used to lower the platform. Contact a qualied/
competent person for repairs.
3.4-7 Overload status
Mode/Condition
Indicator
Light
Audible
Alarm
Drive
Functions
Powered Boom
Functions (Platform
& Base)
Emergency Power
(Platform)
Emergency Power
(Base)
93-99% of platform capacity On Off Enabled Enabled Enabled Enabled
Lowered Travel Position, ≥
100% of platform capacity
Flashing Pulsing Enabled Enabled Enabled Enabled
Elevated Travel Position, ≥
100% of platform capacity
Flashing Pulsing Disabled Disabled Enabled Enabled
1702AA
FAMILIARIZATION
To order go to Discount-Equipment.com