167
SJ30AJE, SJ30ARJE 196274AF
Base Section 5 – Procedures
Test for 12 volts between LM 29 and battery negative while in Base position.
LM 30 - Variable voltage input from tilt sensor on wire #128.
(Level ground= 1.88 volts… 25% grade= 9.4 volts)
Test between negative and LM 30.
LM 31 - Base speed 2 input on wire 72. 50% of pump speed.
Test continuity on wire 72 between LM 31 and base terminal block.
LM 32 - Base speed 3 input on wire 73. 8% of pump speed.
Test continuity on wire 73 between LM 32 and base terminal block.
LM 33 - Not used.
LM 34 - Not used.
LM35 - SGE reset - 12 volt input through motor controller harness B pin #B4 on wire 01A from SGE reset switch
S25. Emergency controls also provides reset.
Test between LM 35 and battery negative while activating reset switch.