169
SJ30AJE, SJ30ARJE 196274AF
Base Section 5 – Procedures
Flash
Code
DisplayedonMDI ProbabableCause Remedy
0XA08 WATCHDOG ACE3Controllerlogicselfcheck
1.Cyclekeyswitch
2.Factoryreset(ClearEeprom)
3.Replacecontroller.
0XA08 FLASHCHECKSUM
Thesoftwareiscorruptedorthe
flashonthecontrollerisdamaged
1.Cyclekeyswitch
2.Factoryreset(ClearEeprom)
3.Thesoftwarewasnotcorrectlywrittenintotheflash
memoryortheflashmemoryisdamaged.Replacethe
controller.
0XA17 LOGICFAIL#3
FailureinhighcurrentHWprotection
circuit
1.Cyclekeyswitch
2.Factoryreset(ClearEeprom)
3.Hardwareprobleminlogiccircuitcardforhighcurrent
(overload)protection.Internalissue.Replacecontroller.
0XA26 SENS.KO Thecurrentsensorisdamaged.
1.Cyclekeyswitch
2.Factoryreset(ClearEeprom)
3.Oneofthecurrentsensor,usedtomeasurethevalueon
themotorphases,isdamaged.Internalissue.Replace
controller.
0XA27 PHASEKO
Oneofthephasesonthedrive
motorsisopen
Checkbatterycablestothedrivemotors
0XA28 PUMPVMNLOW
Pumpmotorislowcomparedto
PWMsignalapplied.
1.CheckwiringtoPump/Motor
2.TestMotor
3.ReplaceMotor
0XA29 PUMPVMNHIGH
Pumpmotorishighcomparedto
PWMsignalapplied.
1.CheckwiringtoPump/Motor
2.TestMotor
3.ReplaceControllerifMotortestsOK.
5.6-10 ZAPI MDI-CAN Controller Master Codes